Description
Carrier® Air Conditioners with Puron® refrigerant provide a collection of features unmatched by any other family of equipment. The 24ACC4 has been designed utilizing Carrier’s Puron® refrigerant. The environmentally sound refrigerant allows you to make a responsible decision in the protection of the earth’s ozone layer.
FEATURES / BENEFITS
Efficiency
- 14.0 SEER / 11.0 – 13.5 EER (based on tested combination)
- Microtube Technology™ refrigeration system
Reliability
- Puron® refrigerant
- Scroll compressor
- Internal pressure relief valve
- Internal thermal overload
- Filter drier
Durability
WeatherArmor™ protection package:
- Solid, durable sheet metal construction
- Dense wire coil guard
Applications
- Long–line – up to 250 feet (76.20 m) total equivalent length, up to 200 feet (60.96 m) condenser above evaporator, or up to 80 ft. (24.38 m) evaporator above condenser (See Longline Guide for more information.)
- Low ambient (down to –20°F/–28.9°C) with accessory kit
NOTE: Always refer to the AHRI directory (www.ahridirectory.org) for the most up–to–date ratings information.
Dimensions | |
---|---|
Length | 31.1875 Inches (in) |
Width | 31.1875 Inches (in) |
Height | 31.8125 Inches (in) |
Weight | 151 Pounds (lbs) |
Attributes | |
Air Flow Direction | Vertical |
Brand | Carrier |
CBU - Compressor Bearing Unit | Yes |
CFM | 2614 |
Color | Gray |
Compressor Type | Scroll |
Condenser Motor HP | 1/10 HP |
Condenser Motor RPM | 1100 |
Condenser Motor Speeds | Variable |
Condenser Motor Type | Direct Drive |
Cooling Capacity | 29600 |
Cooling Rated Capacity (Btu/h) | 30000 |
Country of Origin | USA |
Cycle/Hertz | 60 Hz |
EER | 11.5 |
ETL Listed | No |
Energy Star Rated | No |
Fins per Inch (FPI) | 25 |
Full Load Amps | 0.75 |
Inverter | No |
Liquid Line Fitting Type | Sweat or Braze |
Liquid Line Size (OD) | 3/8" |
Locked Rotor Amps (LRA) | 67.8 |
Maximum Overcurrent Protection (MOCP) | 25 |
Maximum Piping Length | 250' |
Metering Device | TXV/TEV - Thermostatic Expansion Valve |
OPT Code | 1P24ACC430A003-BO |
Phase | Single |
Product Family | 24ACC4 |
Prop 65 | Yes |
Rated Current Amps (RCA) | 12.8 |
Rated Load Amps (RLA) | 12.8 |
Refrigerant | R-410A |
Rows | 1 |
SEER | 14 |
Sound Level (dBA) | 73 |
Stage | Single |
Suction Line Fitting Type | Sweat or Braze |
Suction Line Size (OD) | 3/4" |
Tonnage | 2.5 |
UL / ETL Listed | No |
UL Listed | Yes |
UL Recognized | Yes |
Voltage | 208-230 VAC |
Application Guide
Puron Refrigerant Systems Single- and Two-Stage Residential Piping and Long Line Guideline 24ACC4
Brochure
Comfort Series Air Conditioners - Consumer Brochure 24ACC4
Checklist
Residential Split System Air Conditioners and Heat Pumps Dealer Setup Checklist 24ACC4
Systèmes résidentiels de climatiseurs et de thermopompes bibloc LISTE DE VÉRIFICATION DU CONCESSIONNAIRE 24ACC4
Installation
24ACA Comfort Series Air Conditioner with Puron, Sizes 18 to 60, 1-1/2 to 5 Nominal Tons 24A
24ACS Comfort Series Air Conditioners with R-22 Refrigerant 24A
24AAA5, 24AAA6 24ABB3, 24ABC62 4ACA4, 24ACC4 Aires acondicionados de una sola etapa de la Serie Comfort™ con refrigerante Puron® 1-1/2 a 5 toneladas nominales 24ACC4
24AAA5, 24AAA6 24ABB3, 24ABC62 4ACA4, 24ACC4 Climatiseur ComfortMC Series à un étage avec frigorigène PuronMD 1 1/2 à 5 tonnes nominales 24ACC4
24AAA5, 24AAA6, 24ABB3, 24ABC6, 24ACA4, 24ACC4 Climatiseurs série Comfort™ à un étage avec frigorigène Puronr 1-1/2 à 5 tonnes nominalesNominal Tons 24ACC4
24AAA5, 24AAA6, 24ABB3, 24ABC6, 24ACA4, 24ACC4 Single-Stage Comfort Series Air Conditioners with Puron Refrigerant 1-1/2 to 5 Nominal Tons 24ACC4
Marketing
Mounting Instructions
Owner's Manual
Manual del usuario Sistema de acondicionador de aire central 24A
Guide de l’utilisateur Systèmes de climatisation centrale 24AC
Owner's Information Manual Air Conditioning System 24AC
MANUEL D’UTILISATION CLIMATISEURS – SYSTÈME BIBLOC POUR FRIGORIGÈNE R--410A 24ACC4
Product Data
24ANA1 Infinity 21 Series Air Conditioner with Puron Refrigerant 24A
24ANA7 Infinity 17 Series Air Conditioner with Puron Refrigerant 24A
24ACC6 Performance 16 Air Conditioner with Puron Refrigerant 24AC
24ACC4 Single-Stage Split System Air Conditioner with Puron Refrigerant 1-1/2 To 5 Tons 24ACC
24ACC4 Single-Stage Split System Air Conditioner with Puron Refrigerant 1-1/2 To 5 Tons 24ACC4
Warranty Card - Date Specific
Carrier Limited Warranty for Air Conditioner and Heat Pump Condensing Units with Puron Refrigerant 24ACC4
Garantie limitée applicable au groupe condenseur des climatiseurs ou des thermopompes utilisant le frigorigène PuronMD 24ACC4
Wiring Diagrams
24ACB3 Comfort Series Air Conditioner with Puron Refrigerant 24A
24ACB4 Comfort Series Air Conditioner with Puron Refrigerant 24A
24ACB6 Comfort Series 2-Stage Air Conditioner with Puron Refrigerant 24A
24ACC6 Comfort Series Air Conditioner with Puron Refrigerant 24A
24ANA7 Infinity Series Air Conditioner with Puron Refrigerant 24A
24APA5 Performance Series Air Conditioner with Puron Refrigerant 24A
Wiring Diagram 24ABA3 Base Series Air Conditioner 24A
Wiring Diagram 24ABA4 Base Series Air Conditioner 24A
Wiring Diagram 24ABR3 Base Series Air Conditioner 24A
Wiring Diagram 24ACA3 Comfort Series Air Conditioner 24A
Wiring Diagram 24ACA4 Comfort Series Air Conditioner 24A
Wiring Diagram 24ACR3 Comfort Series Air Conditioner 24A
Wiring Diagram 24ANA1Infinity Series Air Conditioner 24A
Wiring Diagram 24APA3 Performance Series Air Conditioner 24A
24ACC4 Single-Stage Air Conditioner with Puron Refrigerant 24ACC4
Reviews